TC-32

$1,999.00

USB/Ethernet-Based High-Precision Thermocouple Measurement Device

0.0   Write the first Review
Product Q&A     4 Questions | 4 Answers     Read all Q&A
Key Highlights

USB and Ethernet interfaces

32 differential thermocouple (TC) inputs
- Expandable to 64 TC inputs with TC-32-EXP expansion device
- TC channel-to-host isolation

Easy-to-connect mini-jack connectors

24-bit resolution

3 S/s per channel sample rate

Supports J, K, R, S, T, N, E, and B type thermocouples (software-selectable per channel)

Per channel out-of-range alarm configuration

Cold-junction compensation (CJC) sensor per channel

Open thermocouple detection

8 digital inputs and 32 digital outputs/alarms
- Expandable to 16 digital inputs, and 64 digital outputs/alarms with TC-32-EXP expansion device
- Isolated from TC inputs and host
- 50-pin header connector (cable sold separately)

19” rack mountable

Software

Support for DAQami data acquisition companion software for acquiring data and generating signals

TracerDAQ® for acquiring and displaying data and generating signals

Universal Library includes support for Visual Studio® and Visual Studio® .NET,
including examples for Visual C++®, Visual C#®, Visual Basic®, and Visual Basic® .NET

Universal Library for Android™ includes support and examples for the Android 3.1
platform (API level 12) and later

DASYLab® and NI LabVIEW™ drivers

Linux® open-source drivers

InstaCal™ software utility for installing, configuration, and testing

Supported Operating Systems: Windows® 10/8/7/Vista®/XP, 32-bit or 64-bit;
Android 3.1 (API level 12) and later



Adobe PDF Product Data Sheet - PDF printable
Adobe PDF Product User's Manual - PDF printable
software Software and Driver Downloads

 
TC-32

[+] View Larger Image


 
  • Pricing
  • Reviews
  • Q & A
  • Overview
  • Specifications
  • Included/Optional Software
Part Number Description Price Quantity Purchase
Prices shown are in U.S. dollars for orders placed within the U.S. For international orders, please contact one of our distributors in your area.
TC-32 USB or Ethernet-based 24-bit, 32-channel thermocouple input device with 8 digital inputs and 32 digital outputs/alarms. Includes USB cable, Ethernet cable, power supply, and MCC DAQ software CD
$1,999.00 Add to cart
Other Options
USB-2416 USB-based 24-bit, isolated, high-channel-count multifunction DAQ device
average-rating-4_5 ratings  (16 reviews)
$1,099.00 Add to cart
USB-2416-4AO USB-based 24-bit, isolated, high-channel-count multifunction DAQ device with 4 analog output
average-rating-4_0 ratings  (2 reviews)
$1,299.00 Add to cart
Signal Conditioning Options
TC-32-EXP 24-bit, 32-channel thermocouple input expansion device for TC-32 with 8 digital inputs and 32 digital outputs/alarms. Includes 40-pin expansion cable for connection to host TC-32.
$1,499.00 Add to cart
Accessories & Cables
745690-J001 J-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 1 m
toggle-list More Options...
$31.00 add to cart
745690-J002 J-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 2 m $31.00 Add to cart
745690-K001 K-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 1 m $31.00 Add to cart
745690-K002 K-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 2 m $31.00 Add to cart
745690-T001 T-type thermocouple wire, fiberglass (0 °C to 260 °C, 32 °F to 500 °F) 1 m $31.00 Add to cart
745690-T002 T-type thermocouple wire, fiberglass (0 °C to 260 °C, 32 °F to 500 °F) 2 m $31.00 Add to cart
C40FF-1 Cable, 40-conductor ribbon, female to female, 1 ft.
toggle-list More Options...
$32.00 add to cart
C40FF-10 Cable, 40-conductor ribbon, female to female, 10 ft. $57.00 Add to cart
C40FF-15 Cable, 40-conductor ribbon, female to female, 15 ft. $74.00 Add to cart
C40FF-2 Cable, 40-conductor ribbon, female to female, 2 ft. $32.00 Add to cart
C40FF-20 Cable, 40-conductor ribbon, female to female, 20 ft. $89.00 Add to cart
C40FF-25 Cable, 40-conductor ribbon, female to female, 25 ft. $104.00 Add to cart
C40FF-3 Cable, 40-conductor ribbon, female to female, 3 ft. $36.00 Add to cart
C40FF-4 Cable, 40-conductor ribbon, female to female, 4 ft. $38.00 Add to cart
C40FF-5 Cable, 40-conductor ribbon, female to female, 5 ft. $42.00 Add to cart
C40FF-50 Cable, 40-conductor ribbon, female to female, 50 ft. $183.00 Add to cart
C50FF-1 Cable, 50-conductor ribbon, female to female, 1 ft.
toggle-list More Options...
$32.00 add to cart
C50FF-10 Cable, 50-conductor ribbon, female to female, 10 ft. $57.00 Add to cart
C50FF-15 Cable, 50-conductor ribbon, female to female, 15 ft. $74.00 Add to cart
C50FF-2 Cable, 50-conductor ribbon, female to female, 2 ft. $32.00 Add to cart
C50FF-20 Cable, 50-conductor ribbon, female to female, 20 ft. $89.00 Add to cart
C50FF-25 Cable, 50-conductor ribbon, female to female, 25 ft. $104.00 Add to cart
C50FF-3 Cable, 50-conductor ribbon, female to female, 3 ft. $36.00 Add to cart
C50FF-4 Cable, 50-conductor ribbon, female to female, 4 ft. $38.00 Add to cart
C50FF-5 Cable, 50-conductor ribbon, female to female, 5 ft. $42.00 Add to cart
C50FF-50 Cable, 50-conductor ribbon, female to female, 50 ft. $183.00 Add to cart
CIO-MINI50 Universal screw-terminal board, 50-pin (view dimensional drawing)
$89.00 add to cart
CN-144-JM Type J male thermocouple connector
toggle-list More Options...
$5.00 add to cart
CN-144-KM Type K male thermocouple connector $5.00 Add to cart
CN-144-TM Type T male thermocouple connector $5.00 Add to cart
PS-5V2AEPS Replacement power supply, 12-watt, for TC-32, USB-1602HS Series, USB-1604HS Series, USB-1608HS Series, USB-2416 Series, USB-3110, USB-3112, USB-3114, WEB-TEMP, WEB-TC - plugs available separately
toggle-list More Options...
$29.00 add to cart
Australia Plug Australian interchangeable plug for power supplies $10.00 Add to cart
Europe Plug European interchangeable plug for power supplies $10.00 Add to cart
UK Plug UK interchangeable plug for power supplies $10.00 Add to cart
US Plug US interchangeable plug for power supplies $10.00 Add to cart
SCB-50 Signal connection box, two independent (side-by-side) sets of 50 screw terminals, each connected one-to-one to a 50-pin header for ribbon cable mating
$209.00 add to cart
Software
DAQami™ v3.0 Data acquisition companion software for acquiring data and generating signals
average-rating-4_5 ratings  (22 reviews)
$49.00 Add to cart
DASYLab® LITE Icon-Based Data Acquisition, Graphics, and Control Software
average-rating-5_0 ratings  (3 reviews)
More Options...
$499.00 Add to cart
DASYLab® BASIC Icon-Based Data Acquisition, Graphics, Control, and Analysis Software. Includes standard analysis modules and unlimited module count. - Most Popular
average-rating-4_0 ratings  (1 reviews)
$1,299.00 Add to cart
DASYLab® FULL Icon-Based Data Acquisition, Graphics, Control, and Analysis Software. Includes all DASYLab Basic features plus standard modules, 200 layout windows, unlimited module count, and control sequencer.
average-rating-5_0 ratings  (1 reviews)
$1,799.00 Add to cart
DASYLab® PRO Icon-Based Data Acquisition, Graphics, Control, and Analysis Software. Includes all DASYLab Full features plus advanced signal analysis and control modules.
average-rating-4_0 ratings  (3 reviews)
$2,499.00 Add to cart
DASYLab® RUNTIME DASYLab Runtime allows you to run an existing worksheet application on an additional computer (with compatible hardware configurations)
average-rating-4_0 ratings  (1 reviews)
$449.00 Add to cart
DASYLab® UPD Basic DASYLab upgrade to the latest Basic license
average-rating-5_0 ratings  (1 reviews)
$259.00 Add to cart
DASYLab® UPD Full DASYLab upgrade to the latest Full license
average-rating-5_0 ratings  (1 reviews)
$359.00 Add to cart
DASYLab® UPD Lite DASYLab upgrade to the latest Lite license
average-rating-0_0 (0 reviews)
$99.00 Add to cart
DASYLab® UPD Pro DASYLab upgrade to the latest Pro license
average-rating-0_0 (0 reviews)
$499.00 Add to cart
DASYLab® UPD RT DASYLab upgrade to the latest Runtime license
average-rating-0_0 (0 reviews)
$99.00 Add to cart
TracerDAQ® Pro Out-of-the-box virtual instrument suite with strip chart, oscilloscope, function generator, and rate generator – professional version
average-rating-4_0 ratings  (12 reviews)
$199.00 Add to cart

Product Reviews


Write the first review
Product Q & A




combining TC-32 with Daqlab 2001

Hi we use Dasylab to communicate with a Daqlab 2001 unit via ethernet. Is it possible to use Dasylab to communicate with the TC-32 in addition to the Daqlap from the same PC/Dasylab program? i.e. can we control multiple units from Dasylab at the same time? best regards george

Job Title: professor
Industry: education/research
Application: research


6 months ago

georgeH Loughborough UK


Answers
Yes, DASYLab can communicate with multiple DAQ devices at the same time. You will have no conflicts using an IOtech DaqLab/2001 and a TC32 in the same DASYLab program. Both drivers are compatible with each other.

6 months ago



Was this Answer helpful? Yes (0) / No (0)

Python Support?

Can scripting languages such as Python be used to communicate/record from the TC-32?

Job Title: Test Engineer
Industry:
Application:


7 months ago

jb


Answers
Hello JB - MCC does not currently have formal python support or examples. Some customers have called our Universal Library’s DLL from Python, and several have posted their efforts on the internet

7 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

TC-32 and Matlab

It is possible to use TC-32 with matlab (like USB-TC)?

Job Title: Lecturer
Industry:
Application:


9 months ago

Thanh


Answers
The current MATLAB driver set does not have support for the TC-32. However, Mathworks is actively developing 64-bit drivers to support MCC products in MALAB version R2016. For more information, or to request support for a specific device please contact the Mathworks at www.mathworks.com/support/contact_us

9 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

Using Ethernet - Can I run two TC-30 Boxes, with two TC-32-EXP boxes, through a router to get a total of 128 TC channels?

Job Title: Engineer
Industry:
Application:


13 months ago

SPETE Dubuque IA


Answers
Yes, multiple TC-32/TC-32-EXP configurations can be used to obtain additional temperature inputs. The TC-32/TC-32-EXP is compatible with 10Base-T or 100Base-TX Ethernet ports, hubs, or switches.

13 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

Summary
The TC-32 and TC-32-EXP offer exceptional performance and accuracy for thermocouple (TC) measurement applications at a low cost per channel. Offering both Ethernet and USB ports, the TC-32 provides 32 channels of 24-bit resolution for medium channel installations.

The TC-32-EXP adds 32 high-precision channels to support larger installations.

Accuracy is designed into the product with sigma-delta 24-bit ADCs, differential inputs, TC-to-host isolation and cold-junction compensation (CJC) for each channel to reduce the effects of thermal gradients.

With digital alarming notifications when a temperature exceeds programmed limits, the TC-32 and TC-32-EXP offer the perfect solution for temperature monitoring applications including server rooms, refrigerated storage, and long-run test cells.

Channel Expansion with the TC-32-EXP
Connect a TC-32-EXP expansion device to double the number of TC inputs (64), digital inputs (16), and digital outputs/ alarms (64).

The TC-32-EXP connects to the host TC-32 through a 40-pin expansion connector. The host TC-32 provides all power to the TC-32-EXP.

The TC-32-EXP supports all of the TC input and digital I/O features of the host TC-32, including built-in cold-junction compensation and open thermocouple detection.

USB or Ethernet Interface
The TC-32 can communicate with a host device through either USB or 10/100 Ethernet. By offering both USB and Ethernet ports, the TC-32 is the perfect solution for local or remote monitoring.

TC Input
Connect up to 32 differential TC input channels using the four groups of eight mini-jack connectors on the front panel of each device.

Both the TC-32 and TC-32-EXP support sample rates up to 3 S/s and TC types J, K, R, S, T, N, E, and B. TC types are software-selectable per channel.

Cold-Junction Compensation (CJC)
Each TC input on TC-32 devices has a high-resolution CJC sensor that provides a local cold-junction temperature reference point. This feature ensures the highest level of temperature measurement accuracy.

Data Linearization
After the device performs CJC correction, an onboard microcontroller automatically linearizes the TC data using National Institute of Standards and Technology (NIST) linearization coefficients for the selected TC type.

The data is then output as a 32-bit floating point value in the configured format (voltage or temperature).

Open-Thermocouple Detection (OTD)
TC-32 devices are equipped with OTD for all TC input channels. When enabled, OTD allows users to monitor their TCs and determine if they are broken or disconnected.

Connecting TCs to Common-Mode Voltage Sources
Thermocouple inputs are isolated and thermocouple common-mode voltage may deviate up to 48 VDC or 3.5 VAC (at 60 Hz) from chassis ground without any negative impact to measurement accuracy. Common-mode voltages between channels, however, should not vary more than ±1.4 VDC.

Digital I/O and Alarms
The TC-32 provides up to 8 digital inputs and 32 digital outputs that are electrically isolated from the host device and from the TC-32 analog circuits. This configuration allows users to enable a digital output/alarm for each TC channel.

When an alarm is enabled, its associated output line is driven to the appropriate state determined by the alarm options and input temperature. The alarm configurations are stored in non-volatile memory and loaded at power up. TC-32 input channels are constantly converted on enabled channels and processed for alarm conditions regardless of communications connectivity ensuring proper alarming even if communication to the device is lost.

Alarm outputs can be used to indicate when a temperature threshold has been exceeded. This output can be connected to another device, such as a physical alarm or control system. Each digital output is open-drain, which can sink up to 100 mA for direct drive applications.

The TC-32-EXP provides an additional 8 digital inputs and 32 digital outputs.

Digital I/O signals and alarms are accessible through a 50-pin connector on both the TC-32 and TC-32-EXP.

Power
The TC-32 requires external power. A 5 Volt, 2.4 Amp power adapter (PS-5V2AEPS) is included with the TC-32.

The TC-32 provides power to the TC-32-EXP when they are connected.

Calibration
Both the TC-32 and TC-32-EXP are factory-calibrated using a NIST-traceable calibration process. Specifications are guaranteed for one year. For calibration beyond one year, return the device to the factory for recalibration.

The TC-32 and TC-32-EXP devices also support field calibration so that users can calibrate a device locally.

Analog Input
Sample Rate: 3 S/s
Number of Channels: 32 DI
Resolution: 24 bit
Digital I/O
Number of Channels: 40
TC Type
TC Type: B , E , J , K , N , R , S , T
Transducer
Transducer Type: Thermocouple
Measurement Type
Measurement Type: Thermocouple
Interface List
Interface: USB
Interface: Ethernet
Included Software
TracerDAQ® TracerDAQ® is an out-of-the-box application that allows data to be generated, acquired, analyzed, displayed and exported within seconds of installing Measurement Computing data acquisition hardware. TracerDAQ offers four different data acquisition applications; a Strip Chart, an Oscilloscope, a Function Generator and a Rate Generator, all of which are accessed via a common, easy-to-use menu page.
InstaCal InstaCal installation, configuration, and test software in one package simplifies these important steps as you turn your PC into a measurement system. Installation detects new hardware and configures your computer and DAQ device. Test routines verify that all the board's features are operating, and will speed you to a quick resolution.
Universal Library Universal Library programming libraries for Windows® Visual Studio® programming languages, and others. A complete function library to simplify the configuration and operation of your measurement board. A single, universal set of functions operates all our products so you only have to learn to use our library once.

ULx for NI LabVIEW™ ULx for NI LabVIEW™ Advanced Driver for use with NI LabVIEW™ versions 2010-2016. Allows quick development of instrumentation, acquisition, and control applications with Measurement Computing hardware devices
Universal Library for Android Universal Library for Android Software API used to communicate with supported Measurement Computing DAQ devices over the Android™ 3.1 platform (API level 12) and later. The UL for Android includes example projects and detailed documentation to help users develop, install, and run apps on Android-based devices.

Optional Software
DAQami™ v3.0 DAQami™ v3.0 gives users an easy-to-use drag-and-drop interface that makes acquiring data and generating signals a quick and simple task. Users simply select a supported device, configure device channels and other options, and then select one or more displays to plot the data. When a DAQami acquisition is run, the program acquires and logs data from the selected channels, and plots the data on the displays for viewing.
DASYLab® 2016 Software DASYLab® 2016 Software lets you interactively develop PC-based data acquisition applications by simply attaching functional icons. DASYLab offers real-time analysis, control, and the ability to create custom graphical user interfaces (GUIs). What’s more, in contrast to other graphical programming environments, which can require weeks of training to master, DASYLab has a very short user-learning curve. Many applications can be configured in a few minutes, rather than days or weeks.

TracerDAQ® Pro TracerDAQ® Pro provides four virtual instrument applications used to graphically display and store input data – and generate output signals – within minutes of installing Measurement Computing data acquisition hardware. The applications allow the user to customize appearance, store configurations for future use, save data to a file for export and – with the use of interactive hotspots – change settings while the application is running.